Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38345706

RESUMO

BACKGROUND: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population. Cardiac resynchronization therapy (CRT) implantation in patients with PLSVC is challenging due to a complex anatomy. Moreover, data on CRT implantation in this patient population is scarce. Our aim was to report a series of patients with PLSVC and CRT implantation focusing on challenges and pitfalls. METHODS: Electronic medical databases on patients with CRT implantation at the University Heart Centers in Zurich, Switzerland, and Lübeck, Germany, were screened for individuals with a PLSVC. Clinical and demographic characteristics as well as procedural data were reported in all patients. RESULTS: This study presents six cases with a median age of 66 years. CRT implantation was successful in five patients, leading to a reduced QRS duration and improved left ventricular ejection fraction. Atrial fibrillation, ischemic cardiomyopathy, valvular heart disease, and dilated cardiomyopathy were observed in this group as underlying conditions. Specialized tools, such as active fixation left ventricular leads, were utilized. One patient experienced major complications. CONCLUSIONS: This case series shows that although challenging, conventional endovascular CRT implantation is feasible in PLSVC patients. Specialized tools for visualization and fixation may help. Our experiences highlight the importance of preprocedural evaluation of the anatomy and precise intervention planning.

2.
Int J Cardiol Heart Vasc ; 50: 101325, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419611

RESUMO

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods: A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results: For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions: PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.

3.
Circ J ; 87(12): 1722-1726, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37532529

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal energy source with promising safety and efficacy advantages. We aimed to develop a convenient, safe, effective and fast method of pulmonary vein isolation (PVI) utilizing a penta-spline PFA catheter via a single femoral vein and a venous closure system.Methods and Results: Consecutive patients (n=50; mean age: 63.6±10.7 years, 38% female) presenting with AF (paroxysmal AF: 56%) underwent first-time PVI via PFA. A single ultrasound-guided femoral vein puncture and a single transseptal puncture were used. After PVI using the penta-spline PFA catheter, extra pulse trains were added to the posterior wall for wide antral circumferential ablation. A venous closure system was used and a Donati suture was performed. The pressure bandage was removed after 1 h. A total of 196 PVs were identified and isolated with PFA only. The mean procedural time was 27.4±6.6 min, and the mean dwelling time was 14.4±5.5 min. Time to ambulation was 3.3±3.1 h. No severe complications occurred. During a mean follow-up of 6.5±2.1 months, 41/50 patients (82%) remained in sinus rhythm. CONCLUSIONS: The combination of a single venous puncture, single transseptal puncture approach using PFA and vascular closure device resulted in a 100% rate of acute PVI and an extraordinarily fast procedure and time to ambulation. The rate of periprocedural complications was low.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Catéteres
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37589146

RESUMO

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Assuntos
Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Lactente , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Temperatura
5.
J Interv Card Electrophysiol ; 61(2): 321-332, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32638187

RESUMO

PURPOSE: Studies on predictive scores for very late recurrence (VLR) (recurrence later than 12 months) after second-generation cryoballoon-based pulmonary vein isolation (CB2-PVI) are sparse. We aimed to evaluate the frequency of late recurrence (LR) (later than 3 months) and VLR, and to validate predictive scores for LR and VLR after initial CB2-PVI. METHODS: A total of 288 patients undergoing initial CB2-PVI (66 ± 11 years, 46% paroxysmal) were retrospectively enrolled in the LR cohort. In the VLR cohort, 83 patients with recurrence within 3-12 months or with < 12-month follow-up were excluded. The predictive scores of arrhythmia recurrence were assessed, including the APPLE, DR-FLASH, PLAAF, BASE-AF2, ATLAS, SCALE-CryoAF, and MB-LATER scores. RESULTS: During a mean follow-up of 15.3 ± 7.1 months, 188 of 288 (65.2%) patients remained in sinus rhythm without any recurrences. Thirty-two of 205 (15.6%) patients experienced VLR after a mean of 16.6 ± 5.6 months. Comparing the predictive values of these specific scores, the MB-LATER score showed a reliable trend toward greater risk of both LR and VLR (area under the curve in LR; 0.632, 0.637, 0.632, 0.637, 0.604, 0.725, and 0.691 (p = ns), VLR; 0.612, 0.636, 0.644, 0.586, 0.541, 0.633, and 0.680 (p = 0.038, vs. BASE-AF2, respectively)). Kaplan-Meier analysis estimated patients with higher MB-LATER scores which had favorable outcomes (24-month freedom from LR; 26.0% vs. 56.7%, p < 0.0001, VLR; 53.4% vs. 82.1%, p = 0.013). CONCLUSION: The MB-LATER score provided more reliable predictive value for both LR and VLR. Patients with higher MB-LATER scores may benefit from more intensive long-term follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
6.
Int J Cardiol Heart Vasc ; 29: 100576, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32642555

RESUMO

BACKGROUND: Balloon-based ablation systems for pulmonary vein isolation (PVI) are providing procedural safety and efficacy as well as favourable clinical outcome. Although second-generation laser balloon (LB2) based PVI has been shown safety and efficacy relatively long procedural duration was a strong limitation. The third-generation laser balloon (LB3) offers and automized ablation for rapid PVI. We determined safety, efficacy and procedural characteristics of this new promising ablation system. METHODS AND RESULTS: A total of 15 consecutive patients were prospectively enrolled. All patients underwent PVI using the LB3. A total 59/59 PVs (100%) were successfully isolated. Procedural data was compared to the last 15 consecutive patients treated by the LB2. The median procedure time significantly declined from LB2 (91 (86, 105) min) to LB3 (77 (68, 87) min), p < 0.001. Similarly, the median left atrial dwelling time significantly decreased from LB2 (72 (62, 84) min) to LB3 (45 (38, 52) min), p < 0.0001. The total laser time decreased from LB2 (1920 (1765, 2193) sec) to LB3 (1077 (896, 1165) sec), p < 0.00001. A pure single shot PVI was performed in 18/59 PVs (31%). For major adverse events no differences were detected between the groups (LB2 1/15 (6.7%) and LB3 1/15 (6.7%), p = 0.999). CONCLUSION: The LB3 was safe and effective for PVI. Procedure time, LA dwelling time and total laser time significantly decreased compared to LB2.

7.
Circ J ; 83(12): 2443-2451, 2019 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-31708555

RESUMO

BACKGROUND: Radiofrequency (RF)-based pulmonary vein isolation (PVI) results in a favorable clinical outcome, although its complexity demands a long learning curve. Balloon-based systems have been developed to possibly solve these limitations. The 2nd-generation laser balloon (LB2) offers optimized features for improved tissue contact and visibility. We determined the safety, efficacy and learning curve of the LB2 for PVI.Methods and Results:A total of 45 consecutive patients (89% persistent AF) were prospectively enrolled and divided into 3 groups (T1, T2, T3) of n=15 patients per group. All patients underwent PVI by 2 operators using the LB2. The operators were experienced in RF and cryothermal procedures, but not in laser ablations. A total of 174/177 PVs (98%) were successfully isolated. The median procedure time significantly declined from 132 (114, 158) to 119 (102, 127) and 91 (86, 105) min in T1-3, respectively (P=0.0009). Similarly, the median fluoroscopy time significantly decreased from T1 to T3 (22 (17, 27) vs. 21 (16, 24) vs. 13 (10, 17) min, respectively, P=0.045). Adverse events occurred in 6.7%, with a trend towards a lower complication rate with increasing experience. CONCLUSIONS: The LB2 was safe and effective for PVI, even for operators without any previous experience in laser balloon-based PVI. Procedure time, left atrial dwelling time and fluoroscopy time decreased after a learning curve of 15 cases.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Competência Clínica , Terapia a Laser/instrumentação , Curva de Aprendizado , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...